Aerial Bunched Cables (ABC Cables)

Aerial Bunched Cables

Service Drop Cable(ABC CABLE) are mainly used for electric power transmission, rebuilding of urban and forest regions. They can improve safety and reliance of electrified wire netting.

Type of Service Drop Cable

Cat 6 UTP Data Cable Consists of 23AWG Solid Annealed Bare Copper Conductors, PE Insulated twisted 4 Pair, PE Cross Separator, and LSZH outer jacket with rip cord. These structured cable suitable for 10Gigabyte Ethernet Applications and compatible with all known connection systems, Ideal for high performance workstation applications including voice/data systems, Digital video, Broadband and voice over internet protocol etc.

To be a force that drives our employees, empowers our customers and inspires the world for a better future.

  • Duplex Service Drop
  • Triplex Service Drop
  • Quadruplex Service Drop

The Aerial Bundle Cable can be produced whose construction is phase conductor with neutral bare conductor or phase conductor with insulated neutral conductor.

Duplex Service Drop

Supply of 120-volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.

Concentric strand or compressed 1350-H19 conductor, polyethylene or cross-linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger

Triplex Service Drop

To supply power from the utility lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.

Concentric strand or compressed 1350-H19 conductor, polyethylene or cross-linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger.

Quadruplex Service Drop

Used to supply 3 phase power, usually from a pole-mounted transformer to the user`s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.

Conductors are concentrically stranded, compressed 1350-H19 aluminium. Insulated with either polyethylene or XLPE. Neutral messengers are concentrically stranded 6210 AAAC, AAC or ACSR.

Standards

1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2. B-231 Aluminum Conductors, Concentric-Lay-Stranded.
3. B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4. B-399 Concentric-Lay Stranded 6201-T81 Aluminum Alloy Conductors.
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6. Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474